Fluke 117/323 Electricians Combo Kit, Digital Multimeter and Clamp Meter

Fluke

$418.99
(No reviews yet) Write a Review
SKU:
FLUKE-117-323-Kit
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke 117/323 Electricians Combo Kit, Digital Multimeter and Clamp Meter

Having the right tools for the job is essential. Having them when you need them is even better. Arrive on every jobsite prepared with the Fluke 117/323 electricians multimeter and clamp meter combo kit. The two test tools give you the power of a versatile, rugged multimeter combined with a fast-acting, general-purpose clamp meter.

Whether you work in residential electricity or commercial electrical, both of these test tools are a good fit for the work you need to complete. The kit includes

  • Fluke 117 digital multimeter
  • Fluke 323 clamp meter
  • Tl175 test leads
  • TPAK ToolPak magnetic meter hanger
  • Soft carrying case

The Fluke 117 digital multimeter is built to make your life easier with features like:

  • Non-contact voltage detection
  • AutoV/LoZ function
  • Min/Max/Average readings
  • Frequency measurements
  • Capacitance measurements

In order to ensure youÕre ready to go on many jobsites, the 117 is certified for use in CAT III 600 V environments.

The Fluke 323 clamp meter is a good basic troubleshooting tool for commercial and residential electricians. It includes true rms measurements, optimized ergonomics and a large display for efficient troubleshooting. The small clamp is designed to make measurements in tight cable compartments easier on you and itÕs ideally suited for current measurements up to 400 A or voltage measurements up to 600 V.

Together, the Fluke 117 ElectricianÕs Multimeter and 323 True-rms Clamp Meter give electricians easy to use, time-saving tools for your work.



Key features

  • The right combination of tools an electrician needs on the job
  • Multimeter and clamp meter, test leads, TPAK and carrying case
  • 117: wide array of measurement options all packed into one tool
  • 323: take measurements easily in tight cable compartments


Fluke 117 Digital Multimeter

Specifications
Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10 ¡C to +50 ¡C
Storage temperature-40 ¡C to +60 ¡C
Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/Resolution 600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/Resolution 600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts_ True RMSRange/Resolution 600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts_ True RMSRange/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/Resolution 600 ½ / 1 ½
AccuracyBeeper on < 20 ½, off > 250 ½; detects opens or shorts of
500 _s or longer.
OhmsRange/Resolution 600.0 ½ / 0.1 ½
6.000 k½ / 0.001 k½
60.00 k½ / 0.01 k½
600.0 k½ / 0.1 k½
6.000 M½ / 0.001 M½
Accuracy0.9% + 1
Range/Resolution40.00 M½ / 0.01 M½
Accuracy5% + 2
Diode testRange/Resolution 2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/Resolution 1000 nF / 1 nF
10.00 _F / 0.01 _F
100.0 _F / 0.1 _F
9999 _F / 1 _F
100 _F to 1000 _F
Accuracy1.9% + 2
Range/Resolution> 1000 _F
Accuracy5% + 20%
Lo-Z capacitanceRange 1 nF to 500 _F
Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)Range/Resolution 6.000 A / 0.1 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A continuous overload for 30 seconds max
DC ampsRange/Resolution 6.000 A / 0.1 A10.00 A / 0.01 A
Accuracy1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)_Range/Resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.

    • Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
  • Temperature Range/Resolution: -40 ¡F to 752 ¡F / 0.2 ¡F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Fluke 323 True RMS Clamp Meter

Specifications
AC currentRange 400.0 A
Accuracy2% ±5 digits
(45 Hz to 65 Hz)
2.5% ±5 digits
(65 Hz to 400 Hz)
AC voltageRange 600.0 V
Accuracy1.5% ±5 digits
DC voltageRange 600.0 V
Accuracy1.0% ±5 digits
ResistanceRange/Resolution 400.0 ½/ 4000 ½
Accuracy1.0% ±5 digits
Continuity² 70 ½
AC responseTrue RMS
Data holdYes
SizeH x W x D (mm) 207 x 75 x 34
Max wire diameter30 mm (600 MCM)
Weight265 g
Category ratingCAT III 600 V
CAT IV 300 V
WarrantyTwo-year

Reviews