Having the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.
The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min/Max/Average readings with elapsed time to record signal fluctuations.
Fluke 116 multimeters are independently tested for safe use in CAT III 600V environments.
The Fluke 62 MAX+ infrared thermometer is everything you'd want in your toolbox. Small in size, extremely accurate and yet easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop.
Together, the Fluke 116 HVAC Multimeter and 62 MAX+ Infrared Thermometer give HVAC technicians the right tools for the job.
Key features
Fluke 116 HVAC Multimeter
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance helps prevent false readings due to ghost voltage
- Work in poorly lit areas with the Large white LED backlit display
- True-rms voltage and current for accurate measurements on non-linear loads
- Measures 10 A directly (20 A overload for 30-seconds) without a current clamp
- Resistance, continuity, frequency and capacitance
- Record signal fluctuations using Min/Max/Average and elapsed time stamps
- Easy to use with one hand
- Hands free operation with optional magnetic hanger (ToolPak)
- CAT III 600 V safety rated
Fluke 62 MAX+ Infrared Thermometer
- Measure -30 ¡C to 650 ¡C (-22 ¡F to 1202 ¡F)
- Extremely accurate: up to +1.0 ¡C or + 1.0% of reaching (Fluke 62 MAX+)
- IP54 rating for water resistance and dust proof allow you to work rain or shine and even in the most dirty or dusty industrial sites
- Strong enough to withstand a 3m drop. No worry even if you work from a ladder
- Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box
- Dual lasers: The 62 MAX+ has dual lasers to help you identify area to be measured
Fluke 116 Multimeter
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 | |
Display | 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating Temperature | -10¡C to +50¡C | |
Storage Temperature | -40¡C to +60¡C | |
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
Battery Life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range/Resolution | 600.0 mV / 0.1 mV |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) | |
AC millivolts1 True RMS | Range | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
AC volts1 True RMS | Range/Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
Continuity | Range | 600 ½ / 1 ½ |
Accuracy | Beeper on < 20 ½, off > 250 ½; detects opens or shorts of 500 _s or longer. | |
Ohms | Range/Resolution | 600.0 ½ / 0.1 ½ 6.000 k½ / 0.001 k½ 60.00 k½ / 0.01 k½ 600.0 k½ / 0.1 k½ 6.000 M½ / 0.001 M½ |
Accuracy | 0.9% + 1 | |
Range/Resolution | 40.00 M½ / 0.01 M½ | |
Accuracy | 1.5% + 2 | |
Diode Test | Range/Resolution | 2.000 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/Resolution | 1000 nF / 1 nF 10.00 _F / 0.01 _F 100.0 _F / 0.1 _F 9999 _F / 1 _F 100 _F to 1000 _F |
Accuracy | 1.9% + 2 | |
Range/Resolution | > 1000 _F | |
Accuracy | 5% + 20% | |
LoZ capacitance | Range | 1 nF to 500 _F |
Accuracy | 10% + 2 typical | |
Temperature2 (Type-K thermocouple) | Range/Resolution | -40¡C to 400¡C / 0.1¡C |
Accuracy2 | 1% + 10 | |
Range/Resolution | -40¡F to 752¡F / 0.2¡F | |
Accuracy2 | 1% + 18 | |
AC _amps true-rms (45 Hz to 500 Hz) | Range/Resolution | 600.0 _A / 0.1 _A |
Accuracy | 1.0% + 2 | |
DC _amps | Range/Resolution | 600.0 _A / 0.1 _A |
Accuracy | 1.0% + 2 | |
Hz (V or A input)2 | Range/Resolution | 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. ¥ Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. ¥ Temperature Range/Resolution: -40¡F to 752¡F / 0.2¡F. Ê | ||
Mechanical and General Specifications | ||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g | |
Warranty | 3 years |
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature range | -30¡C to 650¡C (-22¡F to 1202¡F) | |
Accuracy | ±1.0¡C or ±1.0% of reading, whichever is greater -10¡C to 0¡C: ±2.0 -30¡C to -10¡C: ±3.0 | |
Response time (95%) | < 300 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | 12:1 (calculated at 90% energy) | |
Display resolution | 0.1¡C (0.2¡F) | |
Repeatability of readings | ±0.5% of reading or <±0.5¡C (1¡F), whichever is greater | |
Power | AA battery | |
Battery life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0¡C to 50¡C (32¡F to 122¡F) | |
Storage temperature | -20¡C to 60¡C (-4¡F to 140¡F), (without battery) | |
Operating humidity | 10% to 90% RH non-condensing at 30¡C (86¡F) | |
Operating altitude | 2000 meters above mean sea level | |
Storage altitude | 12,000 meters above mean sea level | |
IP rating | IP 54 per IEC 60529 | |
Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
Laser safety | FDA and EN 60825-1 Class II |