Fluke 115 Field Technicians Digital Multimeter

Fluke

$248.99
(No reviews yet) Write a Review
SKU:
FLUKE-115
Weight:
0.00 LBS
Shipping:
Calculated at Checkout
Adding to cart… The item has been added
Fluke 115 Field Technicians Digital Multimeter

Compact true-rms meter for field service technicians

The Fluke 115 field technicianÕs digital multimeter measures True-rms voltage and current with plus resistance, continuity, frequency, and capacitance to meet the needs of a wide variety of field service technicians.

The 115 digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115 provides Min/Max/Average with elapsed time to record signal fluctuations. It also measures:

  • AC and DC voltage to 600V,
  • AC and DC current to 10 A (20 A overload for 30-seconds max).

2019 Best Multimeters, Top Pick Ð GeekWrapped.com

Ê
ÊFluke 115 Field Technicians Digital MultimeterFluke 87V Industrial MultimeterFluke 3000 FC Series Wireless MultimeterFluke 1587 FC Insulation MultimeterFluke 279 FC True-rms Thermal Multimeter
CAT ratingCAT III 600 VCAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
True-rms readings_____
Voltage AC/DC600 V1000 V1000 V1000 V1000 V
Current AC/DC10 A10 A400 mA400 mA2500 A AC (with iFlex)
Resistance40 M½50 M½50 M½50 M½50 M½
Capacitance10,000 _F10,000 _F10,000 _F10,000 _F10,000 _F
Temperature--200.0 ¡C to 1090 ¡Cwith t3000 FC-40 ¡C to 537 ¡CInfrared camera
-10 ¡C to 200 ¡C
Infrared camera----_
Additional
measurement
capabilities
Continuity/diode testFrequency,
continuity/diode test,
motor drive (VFD)
measurement,
duty cycle,
microamps, analog
bar graph, relative
reference
Frequency,
continuity/diode test.
Able to connect to
three 3000 FC
modules.
Frequency, Pi/DAR
timed ratio tests,
continuity/diode test, motor drive (VFD)
measurement,
microamps, relative
reference
Frequency,
continuity/diode test,
motor drive (VFD)
measurement


Key features

  • Compact True-rms digital multimeter for field service
  • Includes: meter, holster, 4 mm PVC-Insulated test lead
  • Easy one-handed operation of the meter
  • Min/Max/Average to record signal fluctuations


Specifications
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy± ([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 ½ / 1 ½
AccuracyBeeper on < 20 ½, off > 250 ½ detects opens or shorts of
500 _s or longer.
OhmsRange/resolution600.0 ½ / 0.1 ½
6.000 k½ / 0.001 k½
60.00 k½ / 0.01 k½
600.0 k½ / 0.1 k½
6.000 M½ / 0.001 M½
Accuracy0.9% + 1
Range/resolution40.00 M½ / 0.01 M½
Accuracy5% + 2
Diode testRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 _F / 0.01 _F
100.0 _F / 0.1 _F
9999 _F / 1 _F
100 _F to 1000 _F
Accuracy1.9% + 2
Range/resolution> 1000 _F
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 _F
Accuracy10% + 2 typical
AC amps True RMS
(45 Hz to 500Hz)
Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A overload for 30-seconds max
DC ampsRange/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2Range/resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40_ to 752_ / 0.2_.
General Specifications
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10_ to + 50_
Storage temperature-40_ to + 60_
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years