Lotus LED Lights 7.5W: LRG3-4RSL | 11W: LRG3-HO-4RSL 4_ Sloped Round Regressed Gimbal

Lotus LED Lights

(No reviews yet) Write a Review
SKU:
LLL-7.5W: LRG3-4RSL | 11W: LRG3-HO-4RSL
Weight:
0.00 LBS
Call for price
Lotus LED Lights 7.5W: LRG3-4RSL | 11W: LRG3-HO-4RSL 4_ Sloped Round Regressed Gimbal

  • Models: 7.5W LRG3-4RSL, 11W- LRG3-HO-4RSL
  • 30¡ Sloped Trim & 20¡ Tilt Ð Ideal for Wall Washing & Sloped Ceilings with 5¡ to 55¡ Pitch
  • Type IC Rated Ð Approved for Direct Contact with Insulation
  • Air-Tight, Wet Location, Insulated and Non Insulated Ceilings
  • CRI 90+ for True Colour Rendering
  • 7.5W model light options: 2700K, 3000K, 3500K, 4000K, 5000K, Dim To Warm 3000K to 2000K, and 5CCT
  • 11W model light options: 5CCT user selectable 2700-3000-3500-4000-5000K or Dim to Warm 3000K to 1800K
  • Triac Dimmable with most CL dimmers 120V input
  • 0-10V Dimmable Option with 120V to 347V input
  • External Driver Inside Connection Box Ð No Junction Box Needed
  • Warranty: 10 Year on Residential, 5 Year on Commercial Installations
  • cULus Listed

Video Overview

Sloped Regressed Gimbals

Technical Specifications

CONSTRUCTION:
4? Sloped Round Regressed Gimbal LED.
30¡ Sloped Trim for Wall Washing and Sloped Ceilings from 5¡ to 55¡.
Class 2 Isolated external driver factory installed inside junction box. One driver for every fixture required.

MOUNTING:
Cut Hole In Ceiling And Snap Fixture In Opening With Attached Spring Clips.
Ceiling Clearance Required: 2 1/2?

  • Default Driver Triac Dimmable: 120V AC Input
  • Optional Driver 0-10V Dimmable: 120V-347V AC Input
  • Power factor: > 0.98
  • Energy Used: 7.5W / 11W
  • Halogen equivalent: 50W / 90W
  • Beam Angle: 38¡ Beam with 20¡ tilt and 360¡ rotation
  • Light colour options: Warm White 2700K, Soft White 3000K, Bright White 3500K, Neutral White 4000K, Daylight White 5000K, Dim to Warm 3000K to 2000K (7.5W model), Dim to Warm 3000K to 1800K (11W model), 5CCT user selectable 2700K to 5000K
  • Light output 7.5W: 2700K 580 lm, 3000K 600 lm, 3500K 620 lm, 4000K 630 lm, 5000K 650 lm, Dim to Warm 500 lm
  • Light output 11W: 2700K 950 lm, 3000K 1020 lm, 3500K 1090 lm, 4000K 1120 lm, 5000K 1120 lm, Dim to Warm 760 lm
  • CRI: 90 +
  • Ambient Operating Temperature: -40¡F (-40¡C) to +104¡F (+40¡C)
  • Compliance: cULus approved, certified to CSA STD. C22.2 No. 250.0
  • Rated: Type IC (Direct Contact with Insulation), Energy Star(7.5W only and except Dim to Warm and 5CCT), Air-Tight

DIMENSIONS:

  • ID 4 1/2?; OD 5 3/4?; Thickness 3? (7.5W) / 4? (11W)
  • Cut out: 4 1/2? to 5?
  • Junction Box Dimensions (with driver inside): 3 3/4? x 3 3/8? x 1 1/2?

Suitable for wet locations and soffit installations.

Installation

ALL FIXTURES MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE ELECTRICAL CODES.

Regressed Gimbal LED Lights Installation:

CONNECTING THE DRIVER:
Open the cover of the junction box. Push and remove the knockout on the side plate. Install standard L16 cable connector. Insert line voltage feed into the cable connector and splice same colour wires using the included quick connectors. Close the cover. Connect the driver to the light fixture Ð the arrows on the male and female parts of the connector between the driver and the fixture should match. Tighten the connector by hand.

OPTIONS FOR LOCATING DRIVER:

Fixture comes connected to the driver by 15? long low voltage cable with waterproof connector in the middle.
Depending on where you want the driver to be you have 2 options:

  1. Locate next to the fixture.
  2. Or install all drivers at one location and use low voltage extension cables to the fixtures. Use only extensions provided by the manufacturer. Available jumper cables are 6 feet (1.8m) and 20 feet (6m). Cables are linkable.
    Maximum run should not exceed 40 feet (12m).

DIMMING:

We recommend LED/CFL dimmers that have a low range adjustment dial. After all fixtures are connected to the dimmer adjust the dial to the lowest position before the lights start to flicker of shut down. This setting depends on the local voltage and number of fixtures per dimmer.

LIST OF COMPATIBLE DIMMERS

WARNING:
DO NOT USE ANY OTHER DRIVERS EXCEPT THE LOTUS DRIVERS THAT ARE INCLUDED WITH THE FIXTURE.
DO NOT CONNECT MULTIPLE FIXTURES TO ONE DRIVER.
DO NOT OPEN THE LIGHT FIXTURE AND THE SIDE PLATES OF THE DRIVER Ð NO SERVICEABLE PARTS INSIDE.

Trim Color Options

Available in White and Black Trim

LRG3-4SRL


LRG3-HO-4SRL

Downloads

Specification Sheets

Spec Sheet LRG3-4RSL
Spec Sheet LRG3-HO-4RSL

Sell Sheet
LRG3-4RSL

Extension cables : EXC-6 | EXC-20

Rough in plates :ÊRIP5 | FRP412

PDF files
LRG3-27K | LRG3-30K | LRG3-35K | LRG3-40K | LRG3-50K | LRG3-32K

pdf file LRG3-HO-5CCT-4RSL at 2700K | pdf file LRG3-HO-5CCT-4RSL at 3000K | pdf file LRG3-HO-5CCT-4RSL at 3500K | pdf file LRG3-HO-5CCT-4RSL at 4000K | pdf file LRG3-HO-5CCT-4RSL at 5000K | pdf file LRG3-HO-4RSL-3018K at 100%

IES files
LRG3-27K | LRG3-30K | LRG3-35K | LRG3-40K | LRG3-50K | LRG3-32K

IES files
IES file LRG3-HO-5CCT-4RSL at 2700K | IES file LRG3-HO-5CCT-4RSL at 3000K | IES file LRG3-HO-5CCT-4RSL at 3500K | IES file LRG3-HO-5CCT-4RSL at 4000K | IES file LRG3-HO-5CCT-4RSL at 5000K | IES file LRG3-HO-3018K-4RSL at 100%

Links to Energy Star 7.5W model LRG3

LRG3-27K | LRG3-30K | LRG3-35K | LRG3-40K | LRG3-50K


CONSTRUCTION:
4? Sloped Round Regressed Gimbal LED.
30¡ Sloped Trim for Wall Washing and Sloped Ceilings from 5¡ to 55¡.
Class 2 Isolated external driver factory installed inside junction box. One driver for every fixture required.

MOUNTING:
Cut Hole In Ceiling And Snap Fixture In Opening With Attached Spring Clips.
Ceiling Clearance Required: 2 1/2?

  • Default Driver Triac Dimmable: 120V AC Input
  • Optional Driver 0-10V Dimmable: 120V-347V AC Input
  • Power factor: > 0.98
  • Energy Used: 7.5W / 11W
  • Halogen equivalent: 50W / 90W
  • Beam Angle: 38¡ Beam with 20¡ tilt and 360¡ rotation
  • Light colour options: Warm White 2700K, Soft White 3000K, Bright White 3500K, Neutral White 4000K, Daylight White 5000K, Dim to Warm 3000K to 2000K (7.5W model), Dim to Warm 3000K to 1800K (11W model), 5CCT user selectable 2700K to 5000K
  • Light output 7.5W: 2700K 580 lm, 3000K 600 lm, 3500K 620 lm, 4000K 630 lm, 5000K 650 lm, Dim to Warm 500 lm
  • Light output 11W: 2700K 950 lm, 3000K 1020 lm, 3500K 1090 lm, 4000K 1120 lm, 5000K 1120 lm, Dim to Warm 760 lm
  • CRI: 90 +
  • Ambient Operating Temperature: -40¡F (-40¡C) to +104¡F (+40¡C)
  • Compliance: cULus approved, certified to CSA STD. C22.2 No. 250.0
  • Rated: Type IC (Direct Contact with Insulation), Energy Star(7.5W only and except Dim to Warm and 5CCT), Air-Tight

DIMENSIONS:

  • ID 4 1/2?; OD 5 3/4?; Thickness 3? (7.5W) / 4? (11W)
  • Cut out: 4 1/2? to 5?
  • Junction Box Dimensions (with driver inside): 3 3/4? x 3 3/8? x 1 1/2?

Suitable for wet locations and soffit installations.


Sloped Regressed Gimbals



Specification Sheets

Spec Sheet LRG3-4RSL
Spec Sheet LRG3-HO-4RSL

Sell Sheet
LRG3-4RSL

Extension cables : EXC-6 | EXC-20

Rough in plates :ÊRIP5 | FRP412

PDF files
LRG3-27K | LRG3-30K | LRG3-35K | LRG3-40K | LRG3-50K | LRG3-32K

pdf file LRG3-HO-5CCT-4RSL at 2700K | pdf file LRG3-HO-5CCT-4RSL at 3000K | pdf file LRG3-HO-5CCT-4RSL at 3500K | pdf file LRG3-HO-5CCT-4RSL at 4000K | pdf file LRG3-HO-5CCT-4RSL at 5000K | pdf file LRG3-HO-4RSL-3018K at 100%

IES files
LRG3-27K | LRG3-30K | LRG3-35K | LRG3-40K | LRG3-50K | LRG3-32K

IES files
IES file LRG3-HO-5CCT-4RSL at 2700K | IES file LRG3-HO-5CCT-4RSL at 3000K | IES file LRG3-HO-5CCT-4RSL at 3500K | IES file LRG3-HO-5CCT-4RSL at 4000K | IES file LRG3-HO-5CCT-4RSL at 5000K | IES file LRG3-HO-3018K-4RSL at 100%

Links to Energy Star 7.5W model LRG3

LRG3-27K | LRG3-30K | LRG3-35K | LRG3-40K | LRG3-50K


ALL FIXTURES MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE ELECTRICAL CODES.

Regressed Gimbal LED Lights Installation:

CONNECTING THE DRIVER:
Open the cover of the junction box. Push and remove the knockout on the side plate. Install standard L16 cable connector. Insert line voltage feed into the cable connector and splice same colour wires using the included quick connectors. Close the cover. Connect the driver to the light fixture Ð the arrows on the male and female parts of the connector between the driver and the fixture should match. Tighten the connector by hand.

OPTIONS FOR LOCATING DRIVER:

Fixture comes connected to the driver by 15? long low voltage cable with waterproof connector in the middle.
Depending on where you want the driver to be you have 2 options:

  1. Locate next to the fixture.
  2. Or install all drivers at one location and use low voltage extension cables to the fixtures. Use only extensions provided by the manufacturer. Available jumper cables are 6 feet (1.8m) and 20 feet (6m). Cables are linkable.
    Maximum run should not exceed 40 feet (12m).

DIMMING:

We recommend LED/CFL dimmers that have a low range adjustment dial. After all fixtures are connected to the dimmer adjust the dial to the lowest position before the lights start to flicker of shut down. This setting depends on the local voltage and number of fixtures per dimmer.

LIST OF COMPATIBLE DIMMERS

WARNING:
DO NOT USE ANY OTHER DRIVERS EXCEPT THE LOTUS DRIVERS THAT ARE INCLUDED WITH THE FIXTURE.
DO NOT CONNECT MULTIPLE FIXTURES TO ONE DRIVER.
DO NOT OPEN THE LIGHT FIXTURE AND THE SIDE PLATES OF THE DRIVER Ð NO SERVICEABLE PARTS INSIDE.

Reviews