| Performance |
| Product Type | Emergency Unit New York City Compliant |
| Description | New York City Approved Steel Emergency Unit |
| Input Power | 5W |
| Lumens | 65lm |
| Lumens (per fixture) | 130lm |
| Electrical |
| Power Factor | 0.8@120V; 0.6@277V |
| Input Voltage | Dual 120/277 Voltage |
| Frequencies | 50/60 Hz |
| Input Current @ 120V (mA) | 50mA |
| Input Current @ 277V (mA) | 30mA |
| Maximum Output Current (Amps) | 0.94A |
| Maximum Output Wattage | 9W |
| Dual Voltage Circuit Operation | No |
| Operating Temperature | 32°F to 122°F (0°C to 50°C) |
| Emergency Illumination | 90 minutes |
| Battery Type | Nickel Cadmium |
| Battery Voltage | 9.6V |
| Recharge Time Required | 24-hours |
| Battery Operating Temperature | 32°C to 122°C (0°F to 50°F) |
| Storage Temperature | 68°F to 86°F (20°C to 30°C) |
| Storage Shelf Life | 3 years before the initial charge. 5 years after initial charge. |
| Self Diagnostics | No, manual test only |
| Remote Test Switch | No |
| Installation |
| Mounting Method | Back/End |
| Mounting Type | Wall Mount |
| Maximum Mounting Height (ft.) | 10 ft |
| Emergency Egress Coverage(ft) Mounting at height of 7.5ft | 10 ft x 3 ft mounted @ 7.5 ft |
| Spacing Criteria for Emergency Egress | 18 ft on center assuming 7.5 ft mounting height with egress path 3 ft out |
| Cold Weather Rated | No |
| Construction |
| Shape | Rectangle |
| Housing Material | Steel Sheet |
| Housing Color | White |
| Remote Capacity | Yes |
| No. of Heads | 2-Lamp Heads |
| Head Shape | Square |
| Remote Head Power (W) | 1W |
| Compliance |
| Listings | UL924 Listed |
| Environment | Suitable for indoor use in dry and damp environments |
| IP Rating | Indoor |
| Certification Model Number | PRLEDNYDXR-82 |
| T20 Compliant | Not Title 20 Compliant |
| California Title 24 JA8 Compliant | Not applicable |
| California Energy Commission (CEC) Status | Lawful for Sales in California |
| City Compliance | New York City Approved |
| FCC | Complies with Part 15 of the FCC Rules |