The Wallpack.S is a small, stylish LED lighting fixture. This LED lighting fixture features heavy-duty die-cast aluminum housing with a molded, high impact, prismatic polycarbonate glass lens. Applications: Corporate Campuses, Recreational Facilities, Walkways and a variety of outdoor lighting applications.
Performance Summary
Lumens Range: 3,1291m – 4,431lm Lumens Per Watt (Typical): 141 CRI: Minimum 70 CRI. Custom CRI available upon request. CCT (Typical): 3000K, 4000K, 5700K Manufactured in the U.S. with parts from U.S. and imported.
Fixture Information
Housing: Bronze / Custom Lens: High Impact Polycarbonate Mounting: Over Recessed Outlet Box / Surface Conduit Diffusion: None
Specifications
UL / CSA Listed: Wet Locations Width: 7.75” Depth: 5.5” Height: 13”
Electrical System Characteristics / Data
Standard AC input: 120-277 VAC EMI filter: 47CFR, part 2, part 15 Power factor: .>9 Total harmonic distortion: <20% Surge protection: IEC/EN 61000-4-5 EMC test standard
Construction
Heavy-duty die-cast aluminum housing with powdercoat finish. Features Prismatic Polycarbonate lens.
Optics
High brightness, high efficiency LEDs. Color temperature options include Cool White (5700K typical), Neutral White (4000K typical) Warm White (3000K typical) with minimum 70 CRI. Custom RGBW colors available. 120° beam angle standard. Optional 80° beam angle available.
Controls
Control options include Occupancy Sensor (OS) and Outdoor Occupancy Sensor (OOS). 120V Button Photocell (PC1) and 208V – 277V Button Photocell (PC2). 100-722V (SGR1) and 480V (SGR2) Surge Protectors. 0-10V (010V) and Step (STEP) Dimming functionality
Mounting
Over Recessed Box and Surface Conduit mounting available.
Ambient Temperature
-40°C to +65°C (-40°F to + 149°F).
Driver
Available in B drive currents (525 mA). Highly reliable. Suitable for dry, damp and wet locations. Compliant to worldwide safety regulations for lighting.
Testing Compliance UL 1598 Issued: 2008/09/17 Ed:3 Rev:2012/10/17 UL Standard for Safety Luminaires CSA C22.2#250.0 Issued: 2008/09/17 Ed:3 Luminaires; General Instruction No.1 2010/01/11, General Instruction No. 2 2012/10/17.
Electrical System
Surge protection meets 10KV/5KA per ANSI/IEEEC62.41. Driver meets maximum harmonic distortion (THD) of 20% and is ROHS compliant. Power Factor = > 0.9.