The Wallpack.Y is a shallow, low maintenance LED lighting fixture. This LED lighting fixture features die-cast aluminum housing with a high impact and heat resistant borosilicate glass lens. Applications: Recreational Facilities, Schools, Walkways and a variety of outdoor lighting applications.
Performance Summary
Lumens Range: 8,862lm - 17,724lm Lumens Per Watt (Typical): 141 CRI: Minimum 70 CRI. Custom CRI available upon request. CCT (Typical): 3000K, 4000K, 5700K Manufactured in the U.S. with parts from U.S. and imported.
Fixture Information
Housing: Dark Bronze / Custom Lens: High Impact / Heat Resistant Borosilicate Glass Mounting: Surface Diffusion: Glass Optical
Electrical System Characteristics / Data
Standard AC input: 120-277 VAC EMI filter: 47CFR, part 2, part 15 Power factor: .>9 Total harmonic distortion: <20% Surge protection: IEC/EN 61000-4-5 EMC test standard S
Construction
Die-cast aluminum housing with textured powdercoat finish with high-impact / heat resistant borosilicate glass. Features hinged front with ½” coin plugs with O-ring for conduit or photocell. Optional Visor (V) and Wire Guard (WG) available.
Optics
High brightness, high efficiency LEDs. Color temperature options include Cool White (5700K typical), Neutral White (4000K typical) Warm White (3000K typical) with minimum 70 CRI. Custom RGBW colors available. 120° beam angle standard. Optional 80° beam angle available.
Controls Control options include Occupancy Sensor (OS) and Outdoor Occupancy Sensor (OOS). Emergency Battery Backup (EM) or Emergency Battery Backup, Cold (EMC). 120V Button Photocell (PC1) and 208V-277V Button Photocell (PC2). 480V up to 150W light engine (HV1). 100-722V (SGR1) and 480V (SGR2) Surge Protectors. 0-10V (010V) and Step (STEP) Dimming functionality.
Mounting
Surface mounting available.
Driver Available in B drive current (525 mA). Highly reliable. Suitable for dry, damp and wet locations. Compliant to worldwide safety regulations for lighting.
Testing Compliance
UL 1598 Issued: 2008/09/17 Ed:3 Rev:2012/10/17 UL Standard for Safety Luminaires CSA C22.2#250.0 Issued: 2008/09/17 Ed:3 Luminaires; General Instruction No.1 2010/01/11, General Instruction No. 2 2012/10/17
Electrical System Surge protection meets 10KV/5KA per ANSI/IEEEC62.41. Driver meets maximum harmonic distortion (THD) of 20% and is ROHS compliant. Power Factor = > 0.9.
Ambient Temperature -40°C to +65°C (-40°F to + 149°F).