Larson Electronics HAL-EMG-48-2L-T5HO Fluorescent Light w/ Emergency Backup Ballast - C1 DII - Hazardous Location Areas

Larson Electronics

(No reviews yet) Write a Review
SKU:
HAL-EMG-48-2L-T5HO
Weight:
0.00 LBS
Call for price
Made in the USAThe Larson Electronics HAL-EMG-48-2L-T5HO Hazardous Area Fluorescent Light Fixture is NRTL Listed for United States and Canada Class 1 Division 2 Groups A, B, C and D - NRTL Certified to UL 1598A listed, has a T4A temperature rating and ideal for open air hazardous locations where flammable chemical/petrochemical vapors may be occassionally encountered.>The HAL-EMG-48-2L-T5HO fixture is a 4 foot long, 2 lamp, Class 1 Division 2 Groups A, B, C and D hazardous area fluorescent light and a good choice for use in applications where space is at a premium. This fixture is T4A temperature rated, comes standard with F54-T5/850/HO bulbs, and is available with optional T12/HO and T8/841 bulbs. The lamps are protected by an aluminum framed hinged glass door secured with four turn latches and the fixture is constructed of copper free aluminum alloy. The lamp reflector is corrosion resistant heavy gauge aluminum and coated with a high gloss reflective finish. This fixture is multi-voltage capable and is NRTL Certified to U.L. 595 and UL 1598A Marine Type approved for use marine environments. The HAL-EMG-48-2L-T5HO provides operators in hazardous locations with a compact, reliable and affordable lighting solution for open areas where flammable chemicals and vapors may occasionally be present.Click Here to EnlargeClick Here to EnlargeClick Here to EnlargeClick Here to EnlargeClick Here to EnlargeClick Here to EnlargeThis fluorescent light works, mounts and is wired like our EPL-48-2L explosion proof fluorescent light fixtures. The main difference is that we attach an extra Bodine ballast box to the unit that adds emergency light functionality to the fixture. This explosion proof emergency light will run the standard 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes. For an additional charge, a second ballast can be added to run a second lamp for 1800 total lumens output for 90 minutes. The battery backup unit includes a switched leg for turning the light fixture on/off without kicking the unit into emergency mode.NOTE ON LAMPS:This fixture comes equipped with F54-T5/850/HO – 54 Watt lamps producing 5,000 lumens per bulb, a 5000 Kelvin color and a 20,000 hour rated service life.Standard Surface Mount Brackets: Each bracket is cinched to the bracket mounting peg on each side of the light. The angle of the bracket is set by tightening two cap screws on either side of the bracket. The cap screws act as a set screw. The bracket itself is mounted via a single bolt hole at the top the bracket. There are two brackets, one on each end of the light. Once the brackets are mounted to a surface (ceiling, floor or wall), the light fixture can be removed from the brackets by loosening the cap screws that hold the bracket to the mounting peg. Mounting brackets are removable. A single through hole enables the operator to install the light to any surface. Pendant mounts are available for operators who wish to mount these fixtures away from the ceiling surface.Suggested Applications:Aircraft maintenance, Oil drilling rigs, Refineries, Solvent and cleaning areas, Chemical manufacturing, Waste treatment plants, Gas processing plants.Made in USA Quality Lamp Options1. Each unit dialectically tested.2. Fixture arrives assembled and lamped to reduce installation time and cost. Adjustable mounting brackets enable the operator to choose any mounting angle for the fixture, where other models may only offer one or three choices.3. Fixture constructed of extruded corrosion resistant copper free aluminum alloy.4. Relamping done via 4 turn latches, which enable the operator to unlatch the hinged door and access the lamps.5. Heavy gauge extruded aluminum reflectors with high gloss reflective finish. Resists dents and corrosion.6. 1/2" or 3/4", threaded access hole for wiring conduit. 7. Units can be wired end to end in series.F54-T5/850/HO – 54 Watt, 5000 lumens per bulb, 20,000 hours life, 5000 Kelvin color Specifications / Additional Information HAL-EMG-48-2L-T12HO Hazardous Area RatingsNRTL Listed for United States & Canada Class 1 Division 2, Groups A, B, C, DLamp Type: Fluorescent NRTL Certified to UL 595 Outdoor Marine Type (Saltwater)Dimensions: W-7" L-49 3/4 " H-6 1/8 " NRTL Certified to UL 1598A Marine TypeWeight: 33 Lbs California Title 24 CompliantVoltage: Multi- 120V-60hz 220V-50hz 240V-60hz 277V-60hz Switch Leg for Powering Light On/OffTotal Watts: 108 watts* Total Lumens: STD-T5-HO Bulbs 10,000 Luminous Efficacy: STD-T5-HO Bulbs 92 Lm/W Lamp Life Expectancy: 12,000 Hours Color Temp: 5000K Beam Angle: N/A Ambient Operating Temp Range:-30¡C to +70¡C Operating Temp Range: T4A Rated Mounting: Bracket Standard - Pendant Optional Wiring Hub: 1/2" or 3/4" threaded Special Orders- RequirementsWarranty: YES-3 Years* Contact us for special requirements? Toll Free: 1-800-369-6671HAL-EMG-48-2L-T5HO Dimensional DrawingFax: 1-903-498-3364Wattage totals are lamps only and may vary with different lamps.E-mail:[email protected]

Reviews