Image coming soon

Larson Electronics 56W Hazardous Location LED Fixture - C1D2 - Corrosion Resistant - Dimmable, Modbus TCP/IP Network

Larson Electronics

(No reviews yet) Write a Review
SKU:
HALSS-ANC-48-2L-LED-D-V2
Weight:
0.00 LBS
Call for price
Made in the USA The HALSS-ANC-48-2L-LED-D-V2 Hazardous Location LED Fixture from Larson Electronics is an ETL approved connected lighting solution for Class I, Division 2 Groups A, B, C and D locations. Modbus TCP/IP network capable, this hazardous location LED light has a T4 temperature rating and carries a United States Coast Guard approval, making it ideal for applications such as oil rigs, ships, offshore applications, petrochemical, manufacturing, chemical storage, and water treatment centers. Operators can setup remote access, controls and configurations using the Modbus TCP/IP network controller (via a standard web browser). This four foot long, two lamp 0-10V dimmable LED fixture is ideal for operators seeking a top quality hazardous location light that will reduce operating costs, improve lighting quality and reduce downtime incurred from frequent servicing intervals. The HALSS-ANC-48-2L-LED-D-V2 hazardous area LED light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class I Division 2 rated fixture is constructed of non-corrosive materials including a 304 stainless steel housing, a poured in gasket for reliable sealing, and an impact resistant acrylic diffuser. Our LED T series lamps included with this fixture add greater light output, longer lamp life and add even better resistance to damage from vibration and impacts. Corrosion resistant stainless steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This LED light fixture features 0-10V dimming capabilities. This gives operators the ability to manually adjust the brightness of the LED lamp quickly and easily. The 0-10V dimming allows for adjustments to fit the brightness needs of any lighting situation. A 0-10V dimmable light works through the use of a DC control signal that ranges between zero and ten volts. The basic idea is that at 10 volts of input the light is at its brightest level with 0 volts being the lowest possible dimness setting. The smooth, continuous and flicker-free dimming of a 0-10V dimmable LED light is ideal for a wide range of different lighting applications. We now offer our second generation LED tube lamps with this fixture which have increased this hazardous location light`s performance. This two lamp HAZLOC LED linear fixture is lighter in weight and produces more light than hazardous location fluorescent fixtures. The four foot long LED tube design bulbs included with this unit are rated at 50,000 hours of service life, which is over twice as long as standard T8 bulbs. This fixture is UL 844 rated and Class I Division II, Groups A, B, C, D approved. The HALSS-ANC-48-2L-LED-D-V2 also carries UL 1598A and UL 595 outdoor marine ratings and meets US Coast Guard specifications. This lamp offers the extreme durability, high efficiency and long lamp life of high power LEDs in a proven hazardous location fixture design, making it a reliable and affordable lighting solution for open areas where flammable chemicals and vapors may occasionally be present. Click here to read the NEC description for explosion proof and hazardous locations. Aevum Network Controlled Lighting Solution: The Aevum Network Controlled Lighting Solution from Larson Electronics enables connected and intelligent illumination using cutting-edge and existing networks. Using Modbus TCP/IP or DALI (for fixtures with dimming features), businesses can seamlessly control lights and sensors from remote locations, without traditional light switches. Web-based panels facilitate real-time monitoring of connected equipment and allows operators to switch units on/off, configure activation settings and more. Businesses may utilize their own systems and software with these controllers, ensuring robust flexibility and cost savings (no contracts). The Aevum Network Controlled Lighting Solution can improve productivity in the workplace by automating basic lighting controls and making lighting controls widely accessible in the facility, via local networks or the internet. Operators also have the option to monitor the status of fixtures from a remote location, which can improve maintenance and reduce downtimes. Controls: Controls for the LED fixture is accessible using a web-based control panel. Compatible with HTTP, XML, or Modbus TCP/IP protocols, network configuration is accessible using web-based pages (no programming required). Operators can monitor or setup controls from a remote area using the internet or local IP network and any standard web browser. Functions and controls include: on/off, pulse and monitor. LED indicator lights on the device provide the real-time information about digital input voltage, relay coil, network status and network activity. Password protection for the setup page is available (10 characters maximum). We have eliminated the ballast box normally associated with fluorescent fixtures which reduces overall weight and creates a slimmer unit profile. There is no ballast in this unit and the included LEDT8-28W-V1 LED lamps have a 50,000+ hour service life, both of which result in extreme efficiency and greatly reduced maintenance costs. The solid state design of the LED lamps give this fixture superior resistance to damage from vibration, extremes in temperature and a lamp service life over twice that of standard fluorescent bulbs. Unlike the glass tube design of traditional fluorescent lamps, these LED T-Style lamps have no filaments or fragile housings to break during operation. Instead of using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current applied and emitting light. The LED assembly is mounted to the "tube" constructed from extruded aluminum, with a polycarbonate lens protecting the LEDs. With LED lights, there is no warm up time or cool down time before re-striking and provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than fluorescent lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional fluorescent lighting. The 28 watt LED lamps produce 30% more illumination than standard T8 bulbs while offering lower amp draw and increased reliability. Each lamp produces 3360 lumens at 120 lumens per watt, for a combined 6720 total lumen light output. A HAL-48-2L-T8 hazardous location fluorescent light, with a combined total of 64 watts, draws 0.54 amps at 120 volts AC. This LED version of the same light, with a total of 56 watts, draws only 0.47 amps at 120 volts AC. The HALSS-ANC-48-2L-LED-D-V2 is universal voltage, not multi-tap, and operates on any voltage from 120V to 277V AC 50/60hz without any modifications. We also make a 12/24V AC/DC version for low voltage applications for AC or DC power. Network: The network controller is equipped with one optically-isolated digital input and one SPDT relay contact. Compatible with 9-28V DC, the unit features a 3-position removable relay (N, NO, NC), a 5-position removable power/inputs and an 8-pin RJ-45 port for network connections. Operators can mount the device on walls, surfaces or din rails for space-saving benefits. Energy Consumption Comparison T5HO T8 LED Wattage 108 watts 64 watts 56 watts Amp Draw @ 120V AC 0.90 amps 0.54 amps 0.47 amps Amp Draw @ 220V AC 0.49 amps 0.29 amps 0.25 amps Amp Draw @ 240V AC 0.45 amps 0.27 amps 0.23 amps Amp Draw @ 277V AC 0.39 amps 0.24 amps 0.20 amps Amp Draw @ 12V DC 9 amps 5.34 amps 4.67 amps Amp Draw @ 24V DC 4.5 amps 2.67 amps 2.34 amps Lamp Life Expectancy 20,000 hours 24,000 hours 50,000 hours Color Temperature 5000K / 4100K 4100K 5600K Operation cost per year(12hs/day @ 12c/kWh) $56.77 $33.64 $29.43 This fixture is designed for heavy duty use in applications where intense vibration and corrosive environments may be encountered. Stainless steel construction, high impact acrylic lamp covers, and a Class 1 Division 2 ETL rating make this light ideal for hazardous areas that require illumination with above average dependability. Mounting Options: Unless otherwise specified, our standard, most popular configuration is the adjustable surface mount shown enlarged below. We also offer a pendant mount for those needing to suspend the fixture away from the ceiling surface (i.e. suspend from pipe or conduit). Additional mounting configurations can be customized to meet the requirements on the application. Please contact us for special mounting configurations. Adjustable Surface Mount Brackets: Two stainless steel L-brackets, one on each end of the fixture, enables it to be simply secured to any flat surface. Three through holes provide sufficient mounting for any environment. The angle of the bracket is set by tightening two set screws on either side of the bracket. Once the brackets are mounted to a surface (ceiling, floor or wall), the light fixture can be repositioned by loosening the cap screws, angling the light for maximum illumination, and secured in place by re-tightening the set screws on each mounting bracket. Suspension Mounting: Pendant mount fixtures hang from the ceiling and are suspended by rigid pipe. Each fixture is equipped with two 1/2” NPT hubs, one on each end of the fixture. Operators bring rigid pipe down to the threaded mounting hubs. Wiring is fed down through the rigid pipe to one of the NPT hubs and tied in to the fixture’s lead wires, completing the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture. Suggested Applications: The HALSS-ANC-48-2L-LED-D-V2 is designed for Modbus TCP/IP lighting networks, remote lighting networks, marine wet and damp locations, where corrosion resistant fluorescent lights are required. This lamp is also ideal for locations where heavy vibratory conditions are present. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks. At Larson Electronics, we do more than meet your lighting needs. We also provide replacement, retrofit, and upgrade parts as well as industrial grade power accessories. Our craftsmen can custom build any lighting system and/or accessories to fit the unique demands of your operation. A commitment to honesty, quality, and dependability has made Larson Electronics a leader in the lighting and electronics business since 1973. Contact us today at 800-369-6671 or message [email protected] for more information about our custom options tailored to meet your specific industry needs. Specifications / Additional Information HALSS-ANC-48-2L-LED-D-V2 Hazardous Location 0-10V Dimmable LED Lighting Approvals/Ratings ETL Listing: United States Class I Division 2, Groups A, B, C, D Dimensions: 9.5"W x 54"L x 6.75"H UL 595 outdoor marine Weight: 35 lbs UL 1598A Marine Type (Saltwater) Total Watts: 56 watts Meets US Coast Guard specifications Total Lumens: 6720 0-10V Dimmable Voltage: 120-277 Volts AC 50/60hz or 12-24 Volts DC Password Protected Network Controls Lamp Life Expectancy: 50,000 Hours No Programming Required Efficiency: 90 Lumens per Watt Modbus TCP/IP Connectivity Beam Angle: 150¡ Color Temp: 5600K, 4500K, or 2700K Temp Range: T4C Rated -30¡C to +85¡C Minimum Operating Temp: -30¡C Maximum Case Temp: +90¡C Mounting: Flange Type Surface or Pendant Mount Wiring Hub: 1/2 inch Threaded Network Controller Specs Dimensions: 1.41" x 3.88" x 3.1" Weight: 5 oz Network Type: 10/100 Base-T Ethernet Port Protocols: HTTP, XML, Modbus TCP/IP Power Supply: 9-28V DC Digital Input: (1) Optically Isolated 4-26V DC Current: 950uA @ 4V, 8.5mA @ 26V Relay Contacts: (1) SPDT - 240V AC/30V DC Max @ 12A Relay Modes: On/Off or Pulsed Pulse Timer Duration: 0.1 to 86,400 Seconds Input Functions: Monitor, Local Relay Control, Remote Relay Control LED Indicators: (4) Digital Input Voltage Applied, Relay Coil Energized, Network Linked, Network Activity Special Orders- Requirements Operating Temperature: -40¡C to 57¡C Contact us for special requirements Housing Material: Lexan 940 Polycarbonate Plastic Phone: 1-214-616-6180 Mount: Surface, Wall or DIN Rail Toll Free: 1-800-369-6671 Password Protection: Yes @ Setup (Base 64 Encoding, 10 Characters) Fax: 1-903-498-3364 Connectors: 3-position Removable (Relay- C, NO, NC), 5-position Removable (Power/Input), 8-pin RJ-45 (Network) E-mail: [email protected]

Reviews